{"id":1706,"date":"2018-06-24T15:02:27","date_gmt":"2018-06-24T14:02:27","guid":{"rendered":"http:\/\/www.the-salutation.co.uk\/blog\/?p=1706"},"modified":"2018-07-29T17:30:21","modified_gmt":"2018-07-29T16:30:21","slug":"new-snug-bay-window-roof","status":"publish","type":"post","link":"https:\/\/www.the-salutation.co.uk\/blog\/new-snug-bay-window-roof\/","title":{"rendered":"New Snug Bay Window Roof"},"content":{"rendered":"<p>The problem with the Snug roof was it used to fall towards the house.\u00a0\u00a0 Water would puddle until it was deep enough to overflow to the front.\u00a0\u00a0 I think the roof was built with no fall, then started falling towards the house as the timber framed facade settled with the weight of all the brick infill\u00a0 This photo was taken April 2015.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-844\" src=\"http:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2015\/06\/puddle-on-bay-450x337.jpg\" alt=\"puddle-on-bay\" width=\"450\" height=\"337\" srcset=\"https:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2015\/06\/puddle-on-bay-450x337.jpg 450w, https:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2015\/06\/puddle-on-bay-624x468.jpg 624w, https:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2015\/06\/puddle-on-bay.jpg 1000w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/p>\n<p>Setting up to make the roof fall away from the house turned out to be unreasonably complicated.\u00a0 If I made the rear of the roof straight it would end up 40mm too high at each end so I set up from the front of the curved bay. \u00a0 Wedges cut to fit on top of the existing joists are set to about a 1 in 50 fall which means the roof has ended up higher in the middle than at the ends. Fortunately It looks OK from across the road.<\/p>\n<p>The way to do this is to clamp a new bit of wood to the side of the existing joist, set the new wood to the correct height and angle, then draw a pencil line from the existing joist for cutting. \u00a0 I&#8217;ve gone for a small ventilation gap under the front of the roof and added 100mm of insulation with an air space above before the roof went on.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-1707\" src=\"http:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2018\/06\/snug-roof-wedges-450x337.jpg\" alt=\"snug-roof-wedges\" width=\"450\" height=\"337\" srcset=\"https:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2018\/06\/snug-roof-wedges-450x337.jpg 450w, https:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2018\/06\/snug-roof-wedges-768x575.jpg 768w, https:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2018\/06\/snug-roof-wedges.jpg 1000w, https:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2018\/06\/snug-roof-wedges-624x467.jpg 624w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/p>\n<p>The roof is made from redwood tongue in grove planks (which were cupped making them a real hassle to work with).\u00a0\u00a0 John suggested using a circular saw to cut the curve and it worked a treat.<\/p>\n<p>I&#8217;ve gone for an inch more overhang than before to make sure the roof drips past the stone sill below.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-1712\" src=\"http:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2018\/06\/roof-planked-450x347.jpg\" alt=\"roof-planked\" width=\"450\" height=\"347\" srcset=\"https:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2018\/06\/roof-planked-450x347.jpg 450w, https:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2018\/06\/roof-planked-768x591.jpg 768w, https:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2018\/06\/roof-planked.jpg 1000w, https:\/\/www.the-salutation.co.uk\/blog\/wp-content\/uploads\/2018\/06\/roof-planked-624x480.jpg 624w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/p>\n<p>Hopefully it won&#8217;t rain too much before I get the leadworkers in.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The problem with the Snug roof was it used to fall towards the house.\u00a0\u00a0 Water would puddle until it was deep enough to overflow to the front.\u00a0\u00a0 I think the roof was built with no fall, then started falling towards the house as the timber framed facade settled with the weight of all the brick [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[],"class_list":["post-1706","post","type-post","status-publish","format-standard","hentry","category-building"],"_links":{"self":[{"href":"https:\/\/www.the-salutation.co.uk\/blog\/wp-json\/wp\/v2\/posts\/1706","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.the-salutation.co.uk\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.the-salutation.co.uk\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.the-salutation.co.uk\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.the-salutation.co.uk\/blog\/wp-json\/wp\/v2\/comments?post=1706"}],"version-history":[{"count":12,"href":"https:\/\/www.the-salutation.co.uk\/blog\/wp-json\/wp\/v2\/posts\/1706\/revisions"}],"predecessor-version":[{"id":1831,"href":"https:\/\/www.the-salutation.co.uk\/blog\/wp-json\/wp\/v2\/posts\/1706\/revisions\/1831"}],"wp:attachment":[{"href":"https:\/\/www.the-salutation.co.uk\/blog\/wp-json\/wp\/v2\/media?parent=1706"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.the-salutation.co.uk\/blog\/wp-json\/wp\/v2\/categories?post=1706"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.the-salutation.co.uk\/blog\/wp-json\/wp\/v2\/tags?post=1706"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}